2016年5月12日星期四

why choose us ,not Gicar flow sensor ?

micro oval flow meter :CX-M5-SS, flow range:5~1000ml/min,


one clients from Korea buy 300pcs to measure water for coffe machine, they used Gicar flow sensor before.and choose our micro oval gear flowmeter now

Below is his using condition,

Medium: water

Min flow: 1ml/sec 

Max flow: 10 ml/sec

working temperature: 20~60C

working pressure: 12bar,


You can directly contact sales3@gnflowmeter.com  if have similar using condition.





2016年4月28日星期四

Micro Flow Meter : The second in world

                           Micro Flow Meter


                     Low Micro Flow Meter


Using condition:
precision dosing,hydraulic system ,system monitoring,open/closed loop control
process control,automobile industry,plastic technology,hydraulic system,laundry chemical,additive injection,water treatment,corrosive chemical dispensing,chemical batching,chemical packaging and blending,flow rate ,easurement,oil metering,consumption measurement,ratio control,batching control
hydraulic test stand,metering plant,print process,2 component plant,lacquering plant,closed-loop management

Small Capacity Flow Meter
Medium:
glue,gum,water,fluid,liquid,paints,dyes,chemicals,pharmaceuticals,two-component mixers,petrochemicals,oil,grease,ink,waterbased liquid,adhesive,adbrasive ,dhesive,sealant,hydraulic oil,brake fluid,skydrol,diesel,lubracating,low ,iscosity,gear oil,medium viscosity,methyl alcohol,Methanol,methylbenzene,Toluene
offset ink,high viscosity,polyol,isocyanate,resin,low lubricity,lacquer,clear lacquer,wax,cavity wax,solvent,caustic soda,sodium hydroxide,glycerin,glycol
propylene,triethylene,diethylene,ethylene ,bhylene,molasses,cocoanut oil,corn oil
cotton oil,lard oil,olive oil,palm oil,peanut oil,rape seed oil,rosin oil,soy bean oil,syrup,sugar,electrohydrodynamic 


Model
Flow range
Connection
CX-M2
0.5~150 ml/min
G1/8  female thread
CX-M3
1-300 ml/min
G1/8  female thread
CX-M5
5-1000 ml/min
G1/8  female thread
CX-M6
0.5-100 l/H
G1/4  female thread
CX-M9
5-550 l/H
G1/4  female thread
CX-M12
1~30 L/min
G1/2  female thread
CX-M25
5-110 l/min
G1  female thread
CX-M40
10-250L/min
G1 1/2 female thread
CX-M50
10-500L/min
G2 female thread

accuracy
0.5%
Temperature
-30~80°C(customized)
Pressure
32bar(customized)
output
square-wave pulse
Supply
4-26VDC
material
chamber:SS316L or anodized aluminum

Pls check below parameters to ensure right model for micro flow meter
Using condtion:                              
Medium

Corrosive or Non

Viscosity

Flow range

Working temperature

Working pressure

Used brand
Qty:

If for flow monitor:
Do you need to display total flow or current ? or both ?
If for dosing:
How many litres per batch ? and how long it takes ?


Shanghai Cixi Instrument Co. Ltd

Tel: (86)21-57632436 
Skype: cixi-kitty 
Fax: (86) 21-57634942 
Mob: (86) 18930647859 
Whatsapp: (86) 
15000087545, 18930647859
Email : sales3@gnflowmeter.com
sales15@gninstruments.com 
Website: www.gninstruments.com 
www.gnflowmeter.com 
Address: Rm613, Jiahe Sunny Plaza, No.76 JiuTing Road,
Songjiang District, Shanghai,China,Zip:201615


2016年4月20日星期三

thread and flange for guide radar level meter

one client ask me installation difference for thread and flange for CX-RLM-071, 
1) CX-RLM-071 is guide type radar level meter , 
2)it must be installed by flange ,just pls click the photo, you will know it clearly.

Shanghai Cixi Instrument Co. Ltd

Tel: (86)21-57632436 
Skype: cixi-kitty Fax: (86) 21-57634942 
Mob: (86) 18930647859 
Whatsapp: (86) 
15000087545, 18930647859
Email : sales3@gnflowmeter.com
sales15@gninstruments.com 
Website: www.gninstruments.com 
www.gnflowmeter.com 
Address: Rm613, Jiahe Sunny Plaza, No.76 JiuTing Road,
Songjiang District, Shanghai,China,Zip:201615

2016年4月12日星期二

OEM for Thermocouple for Clients from South Korea

OEM for Thermocouple for Clients from South Korea

 


Our clients from Korea and let us to OEM for Thermocouple 
Pls take a seat and look at blow info detail

This is email from clients, sincerely, the quantity is not too much to us, however we are earnest to treat our every clients 


Finished Product


This is the drawing.
Just in 3 days then our clients make payment for sample and we arrange production for it based on his banklisp.

K thermocouple for max temperature 800C.

Platinum resistance thermocouple

Aluminium alloy

Waterproof electrical connector for thermocouple

Activity thread

Stainless steel 304(SS304) shealth, the material(SS304/SS316) based on your requirements. 

By the way, Our thermocouple/ thermal resistance  has ISO,CE,SGS Certificates.

Welcome inquiry from you!


Shanghai Cixi Instrument Co. Ltd

Tel: (86)21-57632436
Skype: cixi-kitty Fax: (86) 21-57634942
Mob: (86) 18930647859
Whatsapp: (86) 
15000087545, 18930647859
Email : sales3@gnflowmeter.com
sales15@gninstruments.com
Website: www.gninstruments.com
www.gnflowmeter.com
Address: Rm613, Jiahe Sunny Plaza, No.76 JiuTing Road,
Songjiang District, Shanghai,China,Zip:201615





















CX-M3 (1~300ml/min) ultra micro oval gear flow meter for San’an Optoelectronics Co., Ltd

San’an Optoelectronics Co., Ltd is a leader LED manufacturer and they purchase our CX-M3-SS (1~300ml/min)super micro oval gear flow meter to control flow semiconductor,
our new CX-M2 can measure 0.5~150ml/min. as we know the lowest flow in the world.







2016年3月24日星期四

super ultra micro flow meter



Flow Range:  D4: 0.015 to 4.00 GPH (1 to 250 cc/min. or 0.02 cc/cycle)
D20: 0.075 to 20.00 GPH (5 to 1250 cc/min. or 0.10 cc/cycle)

Accuracy: +/-1% 
Repeatability:  +/- 0.1%
Maximum Operating Pressure:  Standard:  3,000 psig (207 bar)
High Pressure: 21,000 psig (1448 bar)
Maximum Differential Pressure:  0250: 5 psi
1250:  15 psi
Temperature Range:  -40˚ to 180˚ F (-40˚ to 80˚ C)
Maximum Viscosity: 100 SSU (25 cp)

NUTATING OPERATING PRINCIPLE
Measurement occurs as the result of the dual orbiting motion of the nutating mechanism as it rolls on the beam.Refer to figures A, B, C and D in sequence. This motion is induced by the fluid as it passes through the meter.This motion is consistent because the differential pressure forces are always great enough to ensure that the nutating mechanism travels the complete volume in each chamber.The process repeats itself 12 to 250 cycles per second, in proportion to the fluid flow through the meter. A flow signal is produced by interrupting the light from a photo-emitting/detecting device. The interruptions are created by a
magnet wire which tracks the magnet encapsulated in the orbiting nutating mechanism. The interruptions are then converted to an electronic square wave output, which is used to quantify the flow.


FLOWMETER FEATURES
The relative simplicity of the MICRO FLOWMETER makes it far less costly than other positive displacement flowmeters which may be capable of measuring similar low flow rates.
Compared to other positive displacement flowmeters, the MICRO FLOWMETER is less susceptible to wear. The reasons for this are as follow:
The parts are so small that the relative velocities amongst the moving parts
are quite low.
All forces acting on one side of the nutator are largely offset by opposing
forces acting on the opposite side.
The ends of the beam are rounded resulting in a rolling motion rather than
sliding during operation.


Since the moving parts are not rigidly attached to each other or the motion
detection mechanism, the MICRO FLOWMETER is capable of service in fluids less
filtered than other devices which may be capable of measuring similar low flow
rates.


Should the MICRO FLOWMETER become clogged with debris, it can be easily
disassembled, cleaned and reassembled with reasonable care in the field.


TD SERIES SPECIFICATIONS
All materials in contact with the fluid media are 316 stainless steel and PTFE.

Ranges:
D4: <0.015-4.00 GPH [1-250 ccpm]
D20: <0.075 -20.00 GPH [5 - 1250
ccpm]


Displacement:
D4: Approximately 50 pulses per
cc
D20: Approximately 10 pulses per
Cc


Accuracy:
+/- 1% of scale

Temp. Range:
-40 To +180° F [-40 To +80°]

Repeatability:
+/- 0.1%

Output Signal:
0 - 5 Volt Square Wave

Maximum Operating Pressure:
3,000 psig [21 MPa] Standard
21,000psi [147 MPa] Added Cost
Option "P"

Process Connections:
1/4"NPT

Max.  P: 5 psi [34kPa] D4
15 psi [102kPa] D20
Conduit Connection:
1/2" NPT

Dimensions: 2.50" D. X
4.63 " L. [6.4 cm D. X 11.8 cm L.]
Weight:
[1.32 Kg.]

Viscosity: 100 SSU [25 cp] Maximum Recommended. Higher Viscosities Reduce
Low Flow Rate Capabilities.



MECHANICAL INSTALLATION AND OPERATING CONSIDERATIONS


1. Once installed and ready to operate, open the bypass and bleed valves wide before slowly starting fluid flow to the Micro flowmeter. Allow the bleed valve to remain open until air and vapors which may have been trapped in the Micro flowmeter have been "bled". If air and vapors are persistent, turn the Micro flowmeter upside down [compression fittings would be useful] while it is running for a short time and then return to upright position.
Close the the bleed and bypass valves and begin normal system operation.[The depicted recommended installation is for systems operating with pressures greater than 20 psi. The bypass and bleed arrangement can safely
be omitted from systems operating at lower pressures].

2. If the Micro flow meter is subject to hydraulic pulsations, check valves may be
required.
3. If it is necessary to disassemble the mechanical portion for cleaning or other
reason, ascertain that the nutator is installed with the inscribed arrow pointing
up [toward the electronic assembly]. Failure to do so may result in loss of
alignment of the motion detection mechanism. Use 4 - 5 foot pounds of torque
on the cap screws when reassembling.